Fs1620 class ii combination firesmoke dampers catalog. The base sheet should be prepared chapter 11 as soon as the architects floor plan is received. Introduction to hvac systems one of the systems series. A slightly positive pressure to reduce outside air infiltration. If the application requires low leakage characteristics, the damper should be provided with seals. The heating or cooling equipment will be brought on at the same time. Ordinary heating, ventilating, and air conditioning duct systems read air pressures at 0. If any of the zone thermostats call for heating or cooling, the zones not calling will have their dampers powered closed, and the zones calling will have their dampers open. The following specifications for damper control hardware are suggested. Model urd round damper forced air zone controls with ma. The urd damper is constructed of heavy 24 gauge galvanized steel with factory rolled stiffening beads. Decisions are made about the types of systems to be used. Hvac damper an hvac damper also called a duct damper is a movable plate, located in the ductwork, that regulates airflow and redirects it to specific areas of the home.
Introduction to commercial building hvac systems and energy. Hvac control dampers can be controlled to help stabilize system pressure and maintain it at comfortable and safe. Nailor industries offers a variety of low leakage rated dampers with. Zoning system design manual 70232103 ducts and dampers 2 size the ductwork in new construction. They may work in the design in technical offices or in the installation in contracting companies. Round or oval damper free area is determined by squaring the radius of the damper and multiplying by 3. Drawing labels, details, and other text information extracted from the cad file.
Air conditioning hvac systems as they relate to energy code requirements. Choose from both rectangle and round configurations designed specifically for things like safety applications, lowleakage and heavy duty industrial needs, and backdraft for pressure relief. Fundamentals of hvac controls course content fundamentals of hvac controls the application of heating, ventilating, and airconditioning hvac controls starts with an understanding of the building and the use of the spaces to be conditioned and controlled. Economizers in air handling systems cedengineering. Site engineer needs to know the basics of hvac systems. Ruskin authority in air control, fire smoke dampers and. The nylon bearings and thermotuff drive shafts insure smooth, quiet operation and provide a thermal barrier to the motor. They can be used in intake, exhaust, or mixed air applications. Series 0100vh and 01x4vh static curtain fire dampers, for use in static fans off systems where the hvac system shuts down in the event of a fire, are ul approved to provide protection of hvac ductwork. In some instances a bypass damper or duct maybe required.
Choose from both rectangle and round configurations designed specifically for things like safety applications, lowleakage and heavy duty. Hvac drawings high rise healthcare office building hvac renovation and new construction drawings. The hvac damper is a simple enough concept, direct or redirect airflow in your air conditioning or exhaust system according to your specific requirements. Airconditioning hvac systems as they relate to energy code requirements. Fire and smoke protection can reduce the risk to human life and minimise potential damage to property and contents. Hvac control dampers are used to help control the flow of outside air, conditioned air, return air, exhaust air and combustion air in hvac systems. Hvac system consists of an air conditioning plant and a thermal distribution system as shown in figure 1. The damper is powered open anytime the unit blower motor is energized.
Hvac interview test with answers for a mep contracting company. Disclaimer of warranties a the sheet metal and air conditioning contractors national association smacna provides its product for informational purposes. This mixed air passes through a filter, a supply fan, and a cooling coil before being discharged. Dampers are tested at an amca certified laboratory using instrumentation and procedures in accordance with amca standard no. In this pdf file submitted there is an interview test contains about 24 technical questions for hvac. Introduction to commercial building hvac systems and. Air dampers perfect for a wide variety of applications at johnson controls, we offer damper controls in a diverse range of models. Dampers 6pack in individual runs of round pipe in an hvac system each sold separately to balance and adjust the flow of air. Ruskins fsd60v proves to be the right fit for mahaska county hospital fsd60v combination firesmoke damper case study the professionals who operate hospitals understand the importance of good air quality in maintaining a healthy environment. Ruskin works with a variety of materials, including galvanized steel, stainless steel, aluminum and fiberglass to match your exact specifications. Model 0110v static curtain fire dampers model series 01x4 1 12 hr. Basic classification of hvac systems for selection guide. Fs1620 class ii combination firesmoke dampers continued performance data specifications note.
Hvac engineers work in the field of heating, ventilation and air conditioning systems. Hvac ducting details cad files, dwg files, plans and details. Introduction to commercial building hvac systems and energy code requirements reid hart, pe, pacific northwest national laboratory. These dampers include springloaded hardware and are constructed from galvanized steel to provide durability. Each zone damper is controlled by its own space thermostat and motorized zone damper. The documents in force at the time the design notice to proceed ntp is. Hvac basics welcome to the school of engineering and. An airside economizer is an hvac control system that can pro vide significant cooling energy. Smacna cad standard second edition v notice to users of this publication 1. This sets the standard for building ventilation in a. Rooms typically have several complete air changes per hour. Commercial control dampers are used in buildings to regulate the flow of air in an hvac system. Schematic diagram of summer ac system5 as shown in the figure, the air conditioning ac plant acts either as a heat source for winter or as a heat sink for summer. Fire and smoke control in multi compartment buildings.
By molding and forming these materials, ruskin constructs the perfect damper for your needs. Hvac damper, fire damper, smoke damper, hvac damper. Easy installation and becomes part of the ductwork. Fire and smoke control systems engineering consultants are well aware of the danger to life and potential damage than can be caused by the spread of smoke through buildings,even if confined to a small area. Dampers are typically used in zoning or zone control systems. With any damper application, the amount of air leakage through the damper should be considered. Every damper is built with performance in mind and tested per amca standards in ruskins laboratory. Today, we offer a complete line of hvac dampers and air control products including volume control. The damper blade is powered by a 24 vac motor with spring return on power loss.
The motorized fresh air damper wgmfad is an internally mounted damper designed to bring in up to 25% fresh air. Hvac damper types most of us, when we think of an air damper, think of rushing to a freshly lit fireplace to flip the soot covered handle that opens the chimney as the room fills with smoke. Original air handling units serving 4th floor surgery s1 and s2 are being replaced with one large rooftop air handling unit above the 1st floor emergency department. A zone damper which is designed to insert into square, round or oval ducting yet has no integrated shell or frame.
Va standard details div 23 hvac steam all details 1 of 2. Air handling units serving the 6th, 7th, 11th, 12th, th, and 15th floor have been replaced and now provide partial or full air conditioning. Design guide for heating, ventilating, and air conditioning systems. This drawing also includes typical hvac ducting details such as traverse join, tappers off sets details, parallel flow branch, splitter damper, elbow construction, radius elbow turning vane, duct insulation, flexible duct connection, duct hangers and support, duct riser supports from floor with typical duct connection cross joint details. Strategies for commissioning of control systems will also be discussed.
Single dampers are not usually made larger than 48 x 76 or 60 x 72 inches for ease in shipping and handling and for construction rigidity. Ul listed, file e27734, ccn xapx united states and xapx7 canada. Demonstrate how to comply with basic energy code provisions using appropriate hvac controls 4. Verify in the construction documentscontrol sequences. This ventilation device does not include an exhaust provision.
Desiged for manual balancing applications in round spiral ductwork. The mdrs25 manual balancing damper has a 7 frame and a butterfly blade. Hvac damper types air flow control heating and cooling. Damper air filters room thermostat supply fan mixed air. We would like to show you a description here but the site wont allow us.
969 818 982 789 176 295 518 1432 998 750 1290 1093 1274 520 924 954 66 1260 80 307 847 428 380 627 475 1226 218 441 299 457 1087 551 290 479 941 1351 803 152 1193